A dielectric structure with an extended radiofrequency field coverage area for human brain magnetic resonance imaging
- 1,2,3,4 ITMO University (St. Petersburg, Russia)
Abstract
Magnetic resonance imaging (MRI) of the extended region of interest (ROI) included both the brain and the cervical spinal cord, presents a significant technical challenge due to the substantial longitudinal extent of the anatomy and the inherent inhomogeneity of the radiofrequency (RF) field at high magnetic field strengths. Conventional dielectric waveguide does not provide uniform excitation across such an extended ROI. The primary objective of this study was to design and numerically evaluate a novel dielectric structure (DS) capable of providing a balanced and homogeneous RF field В1+ distribution simultaneously in the brain and cervical spinal cord tissues, while maintaining local specific absorption rate (SAR) within safe limits. The study was conducted using a numerical phantom and full-wave electromagnetic simulations (CST Studio Suite). A reference dielectric waveguide (DW) was used for comparative analysis. The proposed DS comprised a base cylindrical segment (external diameter 28 cm, length 35 cm, wall thickness 3 cm, permittivity ε = 21) combined with an additional dielectric insert of variable length. Two configurations were investigated: DS «1» (insert length l = 8 cm) and DS «2» (insert length 2l = 16 cm). For each configuration, a parametric analysis was performed by varying the relative permittivity ε of the additional insert from 15 to 25. The RF field characteristics were evaluated within three regions of interest (ROIs): the brain (16 cm), the cervical spinal cord (10 cm), and a combined ROI (26 cm). The analyzed metrics included the mean В1+ amplitude (<В1+>), field homogeneity quantified by the coefficient of variation (COV), and the 10g-averaged specific absorption rate (SAR10g). The parametric analysis revealed that for the DS «1» configuration, none of the permittivity values provided balanced excitation, as the field enhancement was primarily localized in the brain region, with a significantly lower field strength in the cervical spinal cord. In contrast, the extended DS «2» configuration demonstrated a substantial increase in the longitudinal coverage of the RF field. For DS «2», the optimal performance was achieved at ε = 19. At this permittivity, the mean В1+ values were 0.311 μT for the brain ROI, 0.312 μT for the spinal cord ROI, and 0.314 μT for the combined ROI, indicating an excellent balance. Comparative analysis with the reference DW showed that while the proposed DS «2» yielded a 24% lower mean field in the combined ROI, it provided a remarkable 85% increase in the field strength within the cervical spinal cord. Furthermore, the DS «2» exhibited a 26% reduction in SAR10g and substantially improved field homogeneity, with В1+ COV improvements of 25% for the combined ROI, 16% for the brain, and 5% for the spinal cord, compared to the reference DW. Thus, the proposed optimized dielectric structure (DS «2» with ε = 19) effectively addresses the challenge of simultaneous RF excitation of the brain and cervical spinal cord. By extending the longitudinal field coverage and achieving a balanced В1+ distribution, the designed structure significantly improves field homogeneity in the extended ROI in longitudinal direction.
- Received
- 17.08.2026
- Approved after review
- 28.08.2026
- Accepted
- 01.09.2026
How to cite
Попова К.И., Карлик И.А., Будуева С.И., Соломаха Г.А. Диэлектрическая структура с увеличенной областью покрытия радиочастотного поля для магнитно-резонансной томографии мозга человека // Электромагнитные волны и электронные системы. 2026. Т. 31. № 5. С. 15−22. DOI: https://doi.org/10.18127/j15604128-202605-02
References
- Brunner D.O., De Zanche N., Fröhlich J., Paska J., Pruessmann K.P. Travelling-wave nuclear magnetic resonance. Nature. 2009. V. 457. № 7232. P. 994–998. DOI 10.1038/nature07752.
- Tarasova A.A., Anisimov N.V., Pavlova O.S., Gulyaev M.V., Pirogov Yu.A. Magnetic resonance imaging at low signal-to-noise ratio, electromagnetic interferences and hardware imperfections. Electromagnetic Waves and Electronic Systems. 2024. V. 29. № 3. P. 39–40. DOI 10.18127/j5604128-202403-04.
- Popova K.I., Glang F., Bosch D., Scheffler K., Avdievich N.I., Glybovski S.B., Solomakha G.A. An array of paired folded-end dipoles for whole-brain imaging at 9.4 T. Journal of Magnetic Resonance. 2024. V. 368. P. 107791. DOI 10.1016/j.jmr.2024.107791.
- Pohmann R., Speck O., Scheffler K. Signal‐to‐noise ratio and MR tissue parameters in human brain imaging at 3,4 and 9.4 Tesla using current receive coil arrays. Magnetic Resonance in Medicine. 2016. V. 75. № 2. P. 801–809. DOI 10.1002/mrm.25677.
- Gao Ya., Liu T., Hong T., Fang Y., Jiang W., Zhang X. Subwavelength dielectric waveguide for efficient travelling-wave magnetic resonance imaging. Nature Communications. 2024. V. 15. № 1. P. 2298. DOI 10.1038/s41467-024-46638-5.
- Andreichenko A.E., Kroeze H., Klomp D.W.J., Lagendijk J.J.W., Luijten P.R., van den Berg C.A.T. Coaxial waveguide for travelling wave MRI at ultrahigh fields. Magnetic Resonance in Medicine. 2013. V. 70. № 3. P. 875–884. DOI 10.1002/mrm.24496.
- Andreichenko A.E., Luijten P.R., Bluemink J.J., Raaijmakers A.J.E., Lagendijk J.J.W., Van Den Berg C.A.T. Improved RF performance of travelling wave MR with a high permittivity dielectric lining of the bore. Magnetic Resonance in Medicine. 2013. V. 70. № 3. P. 885–894. DOI 10.1002/mrm.24512.
- Yan X., Zhang X., Gore J.C., Grissom W.A. Improved traveling-wave efficiency in 7T human MRI using passive local loop and dipole arrays. Magnetic Resonance Imaging. 2017. V. 39. P. 103–109. DOI 10.1016/j.mri.2017.02.003.
- Zhang B., Sodickson D.K., Lattanzi R., Duan Q., Stoeckel B., Wiggins G.C. Whole body traveling wave magnetic resonance imaging at high field strength: Homogeneity, efficiency, and energy deposition as compared with traditional excitation mechanisms. Magnetic Resonance in Medicine. 2012. V. 67. № 4. P. 1183–1193. DOI 10.1002/mrm.23107.
- Fiedler T.M., Ladd M.E., Bitz A.K. SAR Simulations & Safety. NeuroImage. 2018. V. 168. P. 33–58. DOI 10.1016/j.neuroimage.2017. 03.035.
- Pan S., Yu M., Liu T., Zhang X., Gao Ya. Double-Structure Dielectrics for Efficient Traveling-Wave Magnetic Resonance Imaging. IEEE Antennas and Wireless Propagation Letters. 2026. V. 25. № 3. P. 1264–1268. DOI 10.1109/lawp.2026.3652507.
- Baskaran D., Ding B., Chu S., McElhinney P., Allwood-Spiers S., Williams S.N., Muir K., Fullerton N.E., Porter D.A., Gunamony S. Simultaneous whole‐brain and cervical spine imaging at 7T using a neurovascular head and neck coil with 8‐channel transceiver array and 56‐channel receiver array. Magnetic Resonance in Medicine. 2025. V. 94. № 1. P. 386–400. DOI 10.1002/mrm.30450.
- Christ A., Kainz W., Hahn E.G., Honegger K., Zefferer M., Neufeld E., Rascher W., Janka R., Bautz W., Chen J., Kiefer B., Schmitt P., Hollenbach H.-P., Shen J., Oberle M., Szczerba D., Kam A., Guag J.W., Kuster N. The Virtual Family – development of surface-based anatomical models of two adults and two children for dosimetric simulations. Physics in Medicine and Biology. 2010. V. 55. № 2. P. 23–38. DOI 10.1088/0031-9155/55/2/N01.
