Features of the construction and implementation of the system for the formation of curative effects on biologically active points
Type of article: scientific article
UDC: 615.841
Authors:

S.G.Gurzhin
Ph.D. (Eng.), Associate Professor, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University, the Winner of the Lenin komsomol Prize in Science and Technology,
 Laureate of the Ryazan Region
on Science and Technology and the Silver Medal n. a. Academician V.F. Utkin, Honorary Worker of Higher Professional Education of the Russian
Federation
E-mail: gurzhin@mail.ru
M.B. Kaplan
Ph.D. (Eng.), Associate Professor, Department «Information-measuring and Biomedical Engineering»,
Ryazan State Radio Engineering University

E-mail: mik_kap2001@mail.ru
E.P. Matyukhin
Post-graduate Student, Engineer, Department «Information-measuring and biomedical engineering», Ryazan State Radio
Engineering University

E-mail: matyukhinz@yandex.ru
E.M. Proshin
Dr.Sc. (Eng.), Professor, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University; Honorary Worker of Higher Professional Education of the Russian Federation,
Laureate of the Ryazan Region on Science and Technology n.a. Academician V.F. Utkin

E-mail: proshin39@mail.ru

Abstract:

The means of the system for forming a therapeutic effect on biologically active points are based on the synthesis and formation of biotropic parameters of the electrical and magnetic components of the effect on them.

The principles of electromagnetopuncture therapy have been formulated for a potential increase in the therapeutic effect of therapeutic agents of this type.

The structure of the system is proposed to form a therapeutic effect on biologically active points with a predominant factor in the electrical and magnetic components, consisting of a personal computer with software interfaced with a data collection system, two channels of action with an electrode and an inductor. The software of the system provides the required setting of biotropic parameters and general control.

Pages: 19-25
References
  1. Presman A.S. EHlektromagnitnye polya i zhivaya priroda. M.: Nauka. 1968. 288 s.
  2. Kaznacheev V.P., Mihajlova L.P. Bioinformacionnaya funkciya estestvennyh ehlektromagnitnyh polej. Novosibirsk: Nauka. 1985. 196 s.
  3. Komarov F.I., Rappoport S.I. Hronobiologiya i hronomedicina. M.: Triada-H. 2000. 488 s.
  4. SHurgina A.V. Osnovnye principy hronoterapii: Metodicheskoe posobie. Novosibirsk: NGU. 2002. 46 s.
  5. Kompleksnaya hronomagnitoterapiya: metody i sredstva bioadaptacii vozdejstviya / Pod red. S.G. Gurzhina i E.M. Proshina. M.: Radiotekhnika. 2015. 212 s.
  6. Berkutov A.M., ZHulev V.I., Proshin E.M. Sistemy kompleksnoj magnitoterapii v medicine novogo veka // Vestnik RGRTU. 2001. Vyp. 9. S. 75–86.
  7. Fizioterapiya. Katalog kompanii BTL. 63 s. [EHlektronnyj resurs]. Rezhim dostupa: http://medintech-m.ru/upload/pdf/BTL-physio_CAT_RU207.pdf/, svobodnyj. Zagl. s ehkrana. (data obrashcheniya: 18.05.2018).
  8. Gordeev A.V., Kolchina T.V., Ovcharuk V.N. Generator signalov special'noj formy. Tihookeanskij gosudarstvennyj universitet. 6 s. [EHlektronnyj resurs]. Rezhim dostupa: http://nehb.rf/catalog/010003_000061_3bd58ef7035ca86c5e4d6c4aa8acbe02/, svobodnyj. Zagl. s ehkrana. (data obrashcheniya: 18.05.2018).
  9. Ovcharuk V.N., Gordeev A.V. Postroenie modeli periodicheskoj posledovatel'nosti signalov special'noj formy // EHlektronnoe nauchnoe izdanie: Uchenye zametki TOGU. Habarovsk: 2013. T. 4. № 4. S. 946–957.
  10. Kalakutskij L.I., Akulov S.A., Fedotov A.A. Sistemy ehlektrostimulyacii organov i tkanej [EHlektronnyj resurs]: EHlektron. ucheb. posobie. Samara: Samar. gos. aehrokosm. un-t im. S.P. Koroleva. 2012. 90 s.
Date of receipt: 23 мая 2018 г.