350 rub
Journal Biomedical Radioelectronics №8 for 2018 г.
Article in number:
Virtual means for prompt registration, processing and presentation of biomedical signals in the «Multimag» complex
Type of article: scientific article
UDC: 615.847.8; 616.71
Authors:

S.G.Gurzhin
Ph.D. (Eng.), Associate Professor, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University, the Winner of the Lenin komsomol Prize in Science and Technology,
 Laureate of the Ryazan Region
on Science and Technology and the Silver Medal n. a. Academician V.F. Utkin, Honorary Worker of Higher Professional Education of the Russian
Federation
E-mail: gurzhin@mail.ru
V.I. Zhulev
Dr. Sc. (Eng.), Professor, Head of Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University; Honored Worker of Higher School of Russian Federation,
Laureate of the Ryazan Region on Science and Technology and the Silver Medal n.a. Academician V.F. Utkin

E-mail: zhulev.v.i@rsreu.ru
M.B. Kaplan
Ph.D. (Eng.), Associate Professor, Department «Information-measuring and Biomedical Engineering»,
Ryazan State Radio Engineering University

E-mail: mik_kap2001@mail.ru
V.G. Krjakov
Ph.D. (Eng.), Associate Professor, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University, Laureate of the Ryazan Region on Science and Technology
n.a. Academician V.F. Utkin

E-mail: iit@rgrtu.ryazan.ru
E.M. Proshin
Dr.Sc. (Eng.), Professor, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University; Honorary Worker of Higher Professional Education of the Russian Federation,
Laureate of the Ryazan Region on Science and Technology n.a. Academician V.F. Utkin

E-mail: proshin39@mail.ru
A.V. Shuljakov
Senior Lecturer, Department «Information-measuring and biomedical engineering»,
Ryazan State Radio Engineering University

E-mail: shul_andr@mail.ru

Abstract:

The work deals with hardware and software implementation of the means of registration, processing and presentation of biomedical signals, which allow to make operative measurements and control of the vital parameters of the patient during the magnetotherapy session, as well as diagnostics of his current functional state. The organization in the «Multimag» complex of the biotechnical feedback loop creates new opportunities for timely correction of the characteristics of medical procedures, signaling and automatic disconnection of magnetic influences at patient boundary conditions, significantly increases the objectivity, the accuracy of measuring diagnostic indicators and, in general, the effectiveness of treatment.

To obtain diagnostic information on the patient's condition, the «Multimag» complex developed virtual diagnostic devices that are software-controlled data collection systems in which simulation models of real or hypothetical diagnostic devices are organized. Moreover, software not only controls and displays software, but also the logic of the device's operation. Communication of the program with technical means of registration of biomedical signals is carried out through interface nodes, which are drivers of external devices.

Pages: 11-18
References
  1. Stupakov G.P., Berkutov A.M., SHCHerbinina N.V. Biomedicinskie osnovy hronomagnitoterapii // Biomedicinskie tekhnologii i radioehlektronika. 2004. № 7. S. 4–11.
  2. Baevskij R.M., Ivanov G.G., CHirejkin L.V. i dr. Analiz variabel'nosti serdechnogo ritma pri ispol'zovanii razlichnyh ehlektrokardiograficheskih sistem // Vestnik aritmologii. 2001. № 24. S. 65–86.
  3. Proshin E.M., Grigor'ev E.M., Gurzhin S.G., Kryakov V.G., Kir'yakov O.V. Metody i tekhnicheskie sredstva operativnoj diagnostiki, sinhronizacii i biotekhnicheskoj obratnoj svyazi v kompleksnoj hronomagnitoterapii // Biomedicinskie tekhnologii i radioehlektronika. 2004. № 7. S. 19–25.
  4. SHulyakov A.V. Ispol'zovanie besprovodnyh datchikov obratnoj svyazi v sistemah kompleksnoj magnitoterapii // Biomedicinskaya radioehlektronika. 2010. № 8. S. 13–19.
  5. HEALTH DEVICE PROFILE. Implementation Guidance Whitepaper. URL:http://www.bluetooth.com/Research%20and%20White%20Papers/HDP_Im­plementation_WP_V10.pdf (data obrashcheniya: 23.04.2010).
  6. ZigbeeHealth Care. URL: http://www.zigbee.org/zigbee-for-developers/ applicationstandards/zigbee-health-care/ (data obrashcheniya: 21.01.2018).
Date of receipt: 23 мая 2018 г