350 rub
Journal Technologies of Living Systems №1 for 2015 г.
Article in number:
The comparative characteristic of methods for diagnosis of tularemia and brucellosis
Authors:
I.V. Zharnikova - Dr.Sc. (Biol.), Leading Research Scientist, Science-Practical Laboratory of Preparations for Diagnostic of Dangerous and Other Infections, FGHI Stavropol Antiplague Institute of Rospotrebnadzor E-mail: labdiagn@yandex.ru
S.A. Kurcheva - Ph.D. (Biol.), Senior Research Scientist, Science-Practical Laboratory of Preparations for Diagnostic of Dangerous and Other Infections, FGHI Stavropol Antiplague Institute of Rospotrebnadzor Е-mail: kurcheva@yandex.ru
T.V. Zharnikova - Ph.D. (Biol.), Senior Research Scientist, Laboratory of Training, FGHI Stavropol Antiplague Institute of Rospotrebnadzor Е-mail: snipchi@mail.stv.ru
E.V. Zhdanova - Ph.D. (Biol.), Senior Research Scientist, Science-Practical Laboratory of Preparations for Diagnostic of Dangerous and Other Infections, FGHI Stavropol Antiplague Institute of Rospotrebnadzor Е-mail: snipchi@mail.stv.ru
S.M. Kalnoy - Dr.Sc. (Med.), Leading Research Scientist, Laboratory Indication of Dangerous Infections, FGHI Stavropol Antiplague Institute of Rospotrebnadzor Е-mail: snipchi@mail.stv.ru
Abstract:
The actuality of microbiological monitoring for the detection of pathogens in the environment objects, biological material demands the development of high sensitive and specific diagnostic products and methods of indication .
The aim of this work was to conduct a comparative analysis of immunological methods for the diagnosis of tularemia and brucellosis infectious.
To achieve this goal (used) the diagnostic preparations of experimental and production series FGHI Stavropol antiplague Institute of Rospotrebnadzor was used for setting reactions: indirect haemagglutination (RNGA), immunofluorescence (RIF); analysis: immunoassay (ELISA) and biosensor. Shown аdvantages and disadvantages of each of these methods. The comparative evaluation of diagnostic methods for the following indicators: sensitivity, specificity, time of execution and interpretation of the obtained results, the validity of diagnostic products and the cost of analyses.
The most efficacious of the above methods, biosensor, as it has a high sensitivity to 1.0×103 to 1.0×104 microbial cells in 1 ml, has no re-cross reactions with particles heterologous strains, relatively quick implementation-level analysis - 15 minutes, the information content of the obtained results in the form of computer-characteristic graphs and tables. But these tests are relatively expensive compared to RNGA, RIF and ELISA.
Pages: 41-49
References
- Varfolomeev S.D. Biosensory // Sorosovskijj obrazovatelnyjj zhurnal. 1997. № 1. S. 47-50.
- Byoung C.K., Young H.K. Monitoring Phase Transition in Polymer Using a Quartz Crystal Resonator // Proceedings of the 17th World Congress The International Federation of Automatic Control. Seoul, Korea. July 6-11 2008. P. 2248-2251.
- Dultsev F.N., Kolosovsky E.A. Identifying a single biological nano-sized particle using quartz crystal microbalance. A mathematical model // Sensors and Actuators B: Chemical. 2009. V. 143. № 1. P. 17-24.
- Kon K., Kuwahara T., Shimomura V. Detection of complementary couple of single-stranded DNAs by use of a quartz crystal device for determination of bacteria // Bioscience and Bioengineering. 2011. V. 111. № 2. P. 242-245.
- Melles E., Anderson H., Wallinder D., et al. Electroimmobilization of proinsuline C-peptide to a quartz crystal microbalance sensor chip for protein affinity purification // Analitical Biochemistry. 2005. V. 341. P. 89-93.
- Kompleksnaja programma razvitija biotekhnologijj v Rossijjskojj Federacii na period do 2020 goda; utv. V.V. Putinym 24.04.2012, № 1853p-P8. M. 2012. 120 s.
- Coons A.H., Kaplan M.H. Localisation of antigen in tissue cells // J. Exp. Med. 1950. V. 91. № 1. P. 81-89.
- Clark M.F., Adams A.N. Characteristics of the microplate method of enzyme-linked immunosorbent assay for the detection of plant virus // J. Gen. Virol. 1977. V. 36. № 3. P. 475-483.
- Patent № 2510830 (RF). Sposob poluchenija mikrogravimetricheskogo immunosensora // S.M. Kalnojj, I.V. ZHarnikova, S.P. Dikova i dr.